HPLC, GC and UV-Vis Instrument Troubleshooting

Fault-finding notes from our own service visits — written by the engineers who do them, for the engineer standing in front of the instrument. 16 models we support, 13 guides published so far.

By instrument

Pick the model on your bench. 7 of these have a written guide today — the rest reach an engineer who works on them.

Instrument coverage — models, published guides and answered questions
InstrumentTechniqueBrandGuidesFAQ answers
Agilent 1100 Series HPLCHPLCAgilent Technologies18
Agilent 1200 Series HPLCHPLCAgilent Technologies28
Agilent 1260 InfinityHPLCAgilent Technologies28
Agilent 6890 Gas ChromatographGCAgilent Technologies07
Agilent 7890B Gas ChromatographGCAgilent Technologies17
Agilent 8860 Gas ChromatographGCAgilent Technologies06
Agilent 8890 Gas ChromatographGCAgilent Technologies06
PerkinElmer TurboMatrix HS 40 Headspace SamplerHeadspacePerkinElmer06
Shimadzu GC-2010GCShimadzu07
Shimadzu GC-2014 Gas ChromatographGCShimadzu16
Shimadzu LC-2010HPLCShimadzu38
Shimadzu LC-2030C PlusHPLCShimadzu08
Shimadzu UV-1800 UV-Vis SpectrophotometerUV-VisShimadzu17
Waters 2489 UV/Visible DetectorDetectorWaters06
Waters 2998 PDA DetectorDetectorWaters06
Waters Alliance e2695HPLCWaters08

By symptom

What the instrument is doing, rather than what it is called.

Fault finding

Agilent 7890B Gas Chromatograph

GC Broad or Tailing Solvent Peak: Causes and Fixes

Why the solvent peak in your GC chromatogram turns broad, tails or splits, and the order to check the column cut, splitless settings, liner, backflash and FID gas flows.

HPLC

HPLC Pressure Problems: High, Low and Fluctuating Pressure Explained

What normal HPLC pressure looks like, and how to find the cause of high, low or fluctuating pressure on Shimadzu, Waters and Agilent systems, one connection at a time.

Agilent 1100 Series HPLC

Agilent HPLC Pump Troubleshooting: Pressure Ripple, Leaks and the Purge Valve

How we track down pressure ripple, leaks and purge valve problems on Agilent 1100, 1200 and 1260 Infinity HPLC pumps, in the order that saves the most time.

Shimadzu LC-2010

Shimadzu HPLC Troubleshooting: Common Error Messages and Fixes

The error messages we meet most often on Shimadzu LC-2010 and LC-2010C HT systems, what each one usually means on the bench, and what to check before you call an engineer.

Shimadzu LC-2010

Shimadzu LC-2010C HT Pump Problems: High Pressure, Fluctuation and “No Pump Home”

The pump is the heart of the HPLC. Line filter, check valves, pump seal, and the sensor that counts — what we check, in the order we check it.

Agilent 1200 Series HPLC

HPLC Baseline Noise and Drift: Causes, Diagnosis and Fixes

Most noisy or drifting HPLC baselines come down to ten causes. This is the order our engineers check them in on Shimadzu, Waters and Agilent systems, with a pattern table and a simple stop-flow test.

Maintenance

Calibration

Guides

Questions we get asked

Instrument down right now?

Describe the symptom. Someone who works on that model will answer — not a form, not a ticket number.

What should an HPLC service or AMC enquiry include?

Send the instrument model, module details, laboratory location and a short description of the work required. For a breakdown, include the displayed error and when the symptom started. For an AMC, list the instruments and desired maintenance scope so that visit planning, parts and exclusions can be discussed before a quotation.

Where does Vision Analytical provide analytical instrument support?

Vision Analytical is based in Ambernath, Thane, Maharashtra, and works across Maharashtra and Gujarat. The business has operated since 2022 and serves pharmaceutical laboratories among its customers. Share your exact laboratory address and instrument details to discuss service arrangements; coverage does not imply a branch office or a guaranteed response time in every city.

How can a laboratory make a service scope clear before approval?

Prepare one equipment list that both the laboratory user and the purchasing contact can review. Distinguish planned maintenance from an existing fault and identify any parts already requested. Explain the records your laboratory expects for the work, the access arrangements and the contact responsible for questions. Ask for the proposed activities, exclusions and commercial terms in writing before approval, so that the service discussion and the purchase request refer to the same agreed scope.