GC Service, Repair and AMC in Mumbai and Thane

Gas chromatograph service, repair, spares and AMC for Agilent and Shimadzu GC systems in Mumbai, Thane, Navi Mumbai, Ambernath and Pune.

Key facts

Based in
Ambernath, Thane, Maharashtra · since 2022
Service area
Maharashtra & Gujarat
Mumbai · Thane · Ambernath · Pune · Navi Mumbai · Ahmedabad
Instruments
HPLC, GC, LC-MS and UV-Vis
Brands
Shimadzu, Waters, Agilent Technologies, Thermo Scientific, Merck, PerkinElmer
Services
Installation · Preventive Maintenance · Breakdown Service · AMC · CMC · Calibration · IQ · OQ · PQ · Validation · Software Installation · Training
Reach us
+91 9819424897 (phone) · +91 9819424897 (WhatsApp) · visionanalytical96@gmail.com · customer support info@visionanalytical.co.in
Monday to Saturday, 9:00 am to 6:30 pm IST, closed on Sunday

Gas chromatographs we service

We service the GC systems most often found in pharmaceutical QC, contract testing and research laboratories in Mumbai and Thane. From Agilent Technologies that means the 6890 series, including the 6890 paired with a G1888 headspace sampler for residual solvent (OVI) work, the 7890B with up to two inlets and two detectors, the compact 8860 and the two-channel 8890. From Shimadzu it means the GC-2010 Plus and the GC-2014. We also support the PerkinElmer TurboMatrix HS-40 headspace sampler. On these platforms we work on inlets, detectors and electronic pneumatic control (EPC) modules, with FID, TCD and ECD detector configurations. The GC-2014 is simple enough that most of its faults can be repaired on site rather than by replacing whole boards.

Common GC symptoms and where an engineer looks first
SymptomUsual causeFirst check
Ghost peaksDirty septum or inlet linerReplace the septum and inspect or change the liner
Retention times driftingA change in carrier gas flow or a leakGas supply, septum, column ferrules and gas purifier
Peak tailingThe inlet liner has become activeReplace or deactivate the liner
Baseline keeps climbingColumn bleed from an ageing column or one run past its temperature limitColumn age and the oven programme against the column limit
Broad or tailing solvent peakColumn cut, splitless settings, liner, backflash or FID gas flowsRecut the column, then check the splitless time and FID gas flows
GC spare parts in our catalogue
PartCategoryStock
Autosampler Syringe, 100μLAutosampler PartsIn Stock
FID Jet (GC Detector)Detector PartsLow Stock
GC Injector Liner (Split/Splitless)Injector PartsIn Stock
Graphite/Vespel Ferrule (GC)FerrulesIn Stock

Breakdown repair and what to send us

When a GC stops a QC release, the first message decides how quickly the right engineer and parts arrive. Send the brand and full model, the serial number, what the instrument is doing in your own words, such as "no peak" or "retention times moving", since when it started and whether it started suddenly, any error message on the screen, the date of the last preventive maintenance or calibration, and whether the unit is under warranty or an AMC. Our engineers carry common spares on breakdown calls. We do not promise a fix before seeing the instrument, because one symptom can have several different causes.

Preventive maintenance, AMC and CMC for GC

An AMC covers the engineer's visits and labour, typically two preventive visits a year plus breakdown calls, with spare parts charged separately. A CMC also includes the wear parts, although items such as columns and glassware are often excluded and the contract wording decides. On a GC the consumables are septa, inlet liners, ferrules, the gas purifier or trap, the syringe, the FID jet and the column. Calibration is scheduled every 6 or 12 months according to your own SOP, and we provide IQ, OQ and PQ documents for GC systems so that maintenance and qualification can be planned together.

Independent GC service across Maharashtra and Gujarat

Vision Analytical is based in Ambernath, Thane district, and has worked with laboratories across Maharashtra and Gujarat since 2022, including Mumbai, Thane, Navi Mumbai, Pune and Ahmedabad. Coverage does not mean a branch office or a guaranteed response time in every city; scheduling is confirmed directly with you. We are an independent service company and are not affiliated with or authorised by Agilent Technologies, Shimadzu Corporation or PerkinElmer. Brand and model names are trademarks of their owners and are used here only to describe the instruments we support.

Do you service gas chromatographs in Mumbai and Thane?

Yes. Vision Analytical services and repairs GC systems for laboratories in Mumbai, Thane, Navi Mumbai and Ambernath, and also in Pune and Ahmedabad. Supported systems include the Agilent 6890, 7890B, 8860 and 8890, the Shimadzu GC-2010 Plus and GC-2014, and the PerkinElmer TurboMatrix HS-40 headspace sampler. We are an independent service company.

Why are the retention times drifting on my GC?

Drifting retention times usually point to a change in carrier gas flow or a leak. Check the gas supply, the inlet septum, the column ferrules and the gas purifier first. On systems with electronic pneumatic control a shift usually means something upstream has changed, such as a leaking ferrule or a septum past its life. Ghost peaks point instead to a dirty septum or liner.

Contact

Talk to an engineer, not a call centre

Quotes, spare-part availability and breakdown support — reach us whichever way suits you.

+91 9819424897EmailGet a quote